OCS SECTIONING & SWITCHING / 25 kV AC · 1.5 kV DC CRCC CERTIFIED / TB/T · GB · IEC

Product Catalogue

Sectioning & Switching Equipment for Railway & Metro OCS

Henan Chuangwit manufactures CRCC-certified section insulators, neutral section insulators, HV disconnectors and metro DC disconnectors for 25kV AC railways and 750V/1500V DC urban rail — with project-engineered customization for national railway and metro projects.

TB/T 3036Section Insulators
TB/T 3037Neutral Section Insulators
TB/T 3252Metro Section Insulators
GB 1985HV Disconnectors
IEC 61992-3Metro DC Disconnectors
02

Featured Range

FULL CATALOGUE IN CATEGORY PAGES
TB/T 3111

Contact Wire & Messenger Wire

Copper and copper alloy contact wires and messenger wires per GB/T 12971 and TB/T 3111 series, 65–300 mm².

→
GB/T 11032

Lightning Arrester

Gapless metal-oxide surge arresters for 27.5kV OCS in porcelain and composite housings, 5kA and 10kA classes.

→
TB/T 2075

Splice Clamp

Contact wire and messenger wire splice clamps with at least 95% of wire strength and smooth pantograph passage.

→
GB/T 1984

Circuit Breaker & Load Switch

Vacuum breakers and load switches for 27.5kV traction substations and 12-40.5kV distribution.

→
GB/T 25020

Pillar Series

Lattice steel, H-section and concrete masts plus aluminium emergency repair posts for railway OCS.

→
TB/T 2075.5

Terminal Anchor Clamp

Termination anchor clamps for contact wire and messenger wire up to 350km/h.

→
TB/T 3199

Insulator Series

Porcelain, composite and glass insulators for cantilever, post, suspension and tensioning use.

→
TB/T 2075.11

Electrical Connection Assembly

Contact wire and messenger wire connection clamps for reliable current conduction.

→
TB/T 2075.6

Center Anchor Assembly

Mid-point anchor clamps and ropes for anti-creep anchoring at tension length middles.

→
TB/T 2075

OCS Crossing

S/T/Y type crossings for smooth pantograph transition at railway turnouts, 160-250km/h.

→
TB/T 2075.7

Dropper & Clamp

Integral droppers for suspending contact wire from messenger wire in railway OCS.

→
TB/T 2075.8

Stitch Wire Assembly

Stitch wire clamps and integral droppers for stitched catenary elasticity improvement.

→

Browse All Categories →

03

How to Select

VOLTAGE · SPEED · ENVIRONMENT

By System Voltage

25kV AC mainline railways: section insulators (TB/T 3036) and neutral section insulators (TB/T 3037), plus 27.5kV HV disconnectors. 750V/1500V DC metro: TB/T 3252 metro section insulators and 1.5kV DC disconnectors up to 6000A.

By Line Speed

Mainline AC products are rated up to 160-200 km/h per TB/T 3036/3037 depending on type; metro DC section insulators cover up to 120 km/h per TB/T 3252-2022. Match the sub-model to your design speed at inquiry.

By Service Environment

High-altitude, heavy-pollution, coastal salt-fog and tunnel sections call for enhanced-insulation (-E) variants with ≥430mm reinforced air gap. Test tracks needing AC/DC switching use our 1.5kV/27.5kV dual-purpose disconnector.

Need a quotation or datasheet?