OCS SECTIONING & SWITCHING / 25 kV AC · 1.5 kV DC CRCC CERTIFIED / TB/T · GB · IEC

FYFH-2.0TG-DC Double-Line Section Insulator

FYFH-2.0TG-DC Double-Line Section Insulator

Технические характеристики

МодельFYFH-2.0TG-DC
СтандартTB/T 3252-2022 Rigid Suspension Catenary Busbar and Components for Electrified Railway
Ном. напряжениеDC 1500V (rigid or flexible suspension per sub-model)
Конструктивная скоростьUp to 120 km/h (metro lines)
МатериалыHigh-strength insulating elements; aluminum alloy runners; stainless steel fasteners
МонтажRigid suspension point mounting or flexible in-line series connection

The FYFH-2.0TG-DC flexible double-line metro секционный изолятор is designed and manufactured per TB/T 3252-2022 (Rigid Suspension Catenary Busbar and Components for Electrified Railway) for in-phase electrical sectioning of twin контактный провод catenary on 1500V DC metro and urban rail overhead contact systems. It replaces the legacy FDJYQ-CWL-2 designation in the Henan Chuangwit Railway Equipment catalogue.

The flexible design eases installation in complex metro environments — both контактный проводs are sectioned simultaneously in a single assembly — and keeps operation stable over long service periods. High-strength insulating elements, aluminum alloy runners and stainless steel fasteners, rated for metro speeds up to 120 km/h, -25°C to +45°C, altitudes up to 2,000 m.

Mounting is by rigid suspension point or flexible in-line series connection, matching the контактная сеть suspension type. Drawing number CWLFD2.0TG-DC-00.

Contact Henan Chuangwit Railway Equipment Co., Ltd. for datasheets, drawings and quotations for double-line metro sectioning applications.

Frequently Asked Questions

When is a double-line секционный изолятор needed?

On metro sections with twin контактный провод catenary, both wires must be sectioned together — the double-line unit insulates and bridges both контактный проводs in one assembly.

Which standard applies?

TB/T 3252-2022 (Rigid Suspension Catenary Busbar and Components for Electrified Railway).

Is installation complicated?

No — the flexible design simplifies alignment and tensioning, shortening installation time in tunnel possession windows.

Эксплуатационные характеристики

Условия эксплуатации

Metro tunnel and open-air service from -25°C to +45°C, altitudes to 2,000 m, including humid tunnel atmospheres.

Механические характеристики

Double-wire flexible assembly sections both контактный проводs simultaneously; smooth pantograph transition up to 120 km/h.

Электрические характеристики

High-strength insulating elements provide reliable double-line separation on 1500V DC systems per TB/T 3252-2022.

Применение

Twin-Wire Metro контактная сеть

Simultaneous sectioning of double контактный провод runs.

Stations & Depots

Section separation in station throats and depots.

Humid Tunnels

Materials suited to humid underground service.

Cold Regions

Operation down to -25°C.

Need a quote or datasheet? Написать нам WhatsApp Telegram